• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
  • Advertise
  • Subscribe

Pneumatic Tips

Tips, Trends, Resources, News and Information

  • Blog
  • Industry News
  • Air Preparation
  • Engineering Basics
  • Components
    • Actuators
    • Cylinders
    • Fittings
    • Gears
    • Grippers
    • Pumps
    • Air Compressors
    • Tubing
    • Vacuums
    • Valves
  • Pressure Sensing
  • Design Guide Library
  • Classrooms
    • Pneumatics Classroom
You are here: Home / Air Preparation / Compressed air fail: Remote cooler install

Compressed air fail: Remote cooler install

September 11, 2023 By Paul Heney

Share
Fig. 1. This 100-psi rated compressor is running at higher than rated pressure partly due to poor installation practices. The piping connecting this compressor to its remote cooler is only 2 in.

A wood products company called in a compressed air auditor to have a look at its compressed air system. System reliability was poor, and the staff was having issues with the main compressor, a 200-hp air cooled screw compressor that carried most of the plant load.

This compressor was rated at 100 psi, but recently they found that the plant pressure needed to be increased to provide enough pressure to some critical air demands at the far end of the plant. The main compressor, once reliable, had started to trip out on motor overcurrent, causing expensive unplanned production outages.

The air auditor placed measurement instruments on the system and observed the plant pressure profile. Plant pressure was running at about 100 psi, but due to pressure differential across an air dryer, the pressure at the discharge of the compressors was averaging 108 psi. This was a concern because all the compressors were rated at only 100 psi.

Careful inspection of the main compressor showed a significant issue. The air cooler of the unit was installed remotely about 30 feet away on an outside wall to take advantage of the cool air coming in from outdoors. However, rather than connecting the cooler with 3-in. piping, similar to what was on the compressor discharge, the installers decided to use 2-in. size. This mistake was causing a 6-psi pressure drop between the compressor screw element and the outlet of the cooler. In all, the compressor was running at 14 psi higher than its rating.

Fig. 2. This piping reduction causes a restriction, which overpressures the screw element, causing high motor current and occasional overload trips.

The auditor explained that every 2-psi increase in pressure over the rating of the compressor causes 1% more power to be consumed by the compressor motor. Operating at higher pressure was causing more amps to be drawn by the motor, and due to this, it was running hot. There was 7% more power being consumed by this compressor, causing motor overload.

Recommendations included reducing compressor setpoint to lower levels, upgrading the piping, and maintaining the filters on the air dryer. Once the corrections were made, the reliability improved, and the compressor consumed less energy — a double win!

 

You may also like:


  • Compressed air fail: The mystery filter

  • Compressed air fail: Safety hazard

  • Compressed air fail: Don’t forget the dryer!

  • Compressed air fail: Regulator size

Filed Under: Air Compressors, Air Preparation

Primary Sidebar

Fluid Power World Digital Edition

Fluid Power World Digital EditionBrowse the most current issue of Fluid Power World and back issues in an easy to use high quality format. Bookmark, share and interact with the leading design engineering magazine today.

RSS Featured White Papers

  • eBook: Practical Guide to Pneumatics
  • Saving energy and service cost with electric linear systems
  • White Paper-How to Design Efficient Pneumatic Systems!

Fluid Power Design Guides

fluid
“pt
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for Fluid Power Professionals.
Hose Assembly Tips

Footer

Pneumatic Tips

Fluid Power World Network

  • Fluid Power World
  • Hose Assembly Tips
  • Mobile Hydraulic Tips
  • Sealing and Contamination Tips
  • Fluid Power Distributor Lookup

PNEUMATIC TIPS

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2026 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy