Compressed air fail: Flowmeter position

July 13, 2022 By Paul Heney

Share

A local food company was resizing its compressed air system while renewing its plant operations. To get the sizing correct, the plant maintenance foreman purchased a flow meter to measure the output of the compressors.

The meter was installed with a data logger to capture the flow profile of the plant. The readings showed that the peak flows were 450 cfm, and the average was 300 cfm — so a main compressor sized at 90 kW was purchased and installed.

Shortly after installation, the maintenance foreman was surprised to see low pressure was occurring, indicating the compressor was too small. The compressor was rated at 500 cfm, yet the flow meter still showed peaks of no more than 450 cfm during the highest production times.

A compressed air auditor was called in to investigate and immediately recognized a problem. The plant was using a heatless desiccant dryer to dry the air — and it was consuming purge flow. The flow meter, being of thermal mass design, was installed after the dryer, so did not capture  the 150 cfm of purge in either the peak or average reading.

The auditor examined the flow meter records and found that the system flow during non-production times was a steady 150 cfm, indicating a high level of leakage. He also tested the air dryer and found the purge flow was 60 cfm higher than normal. With some adjustments and leakage repair, the peak plant loading was reduced enough to ride out plant peaks with the new compressor.

Things are not always what they seem when using thermal mass flow meters. It is important to ensure you have a good grasp of the flow requirements upstream of the meter before sizing compressors.

 

You may also like:


  • Compressed air fail: The mystery filter

  • Compressed air fail: Sensor eye blowing

  • Compressed air fail: Safety hazard

  • Compressed air fail: Pressure drop square function

Filed Under: Air Compressors, Air Preparation, Blog

Primary Sidebar

Fluid Power World Digital Edition

Fluid Power World Digital EditionBrowse the most current issue of Fluid Power World and back issues in an easy to use high quality format. Bookmark, share and interact with the leading design engineering magazine today.

RSS Featured White Papers

  • eBook: Practical Guide to Pneumatics
  • Saving energy and service cost with electric linear systems
  • White Paper-How to Design Efficient Pneumatic Systems!

Fluid Power Design Guides

fluid
“pt
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for Fluid Power Professionals.
Hose Assembly Tips

Footer

Pneumatic Tips

Fluid Power World Network

  • Fluid Power World
  • Hose Assembly Tips
  • Mobile Hydraulic Tips
  • Sealing and Contamination Tips
  • Fluid Power Distributor Lookup

PNEUMATIC TIPS

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2026 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy