Compressed air fail: Capacity surprise

May 14, 2024 By Paul Heney

Share

When doing a compressed air audit, it is always recommended to measure the important parameters of the system and analyze the data carefully. Typically, pressure and power (or amps) are monitored, but in some cases measurement of flow comes in handy. In the case of a large plumbing component manufacturer, the installation of flow meters detected a surprising problem with two of their compressors.

The system was made up of six large compressors distributed in three different locations within the plant. The compressor operation was very efficiently coordinated by a central compressor controller. The controller also did some reporting of compressor peak and average flows for the information of the operators.

The system originally had no flow meters installed, but staff were interested in how well the compressors were producing, so flow meters were installed to monitor the output of all the units. When this was completed, data loggers were installed to capture the data for analysis in assessing system operation. This provided quite the surprise! It was discovered that two of their compressors were only producing about half of their rated capacity.

Fig. 1. Staff assumed the 300-hp compressor in this chart was running at full load of 1,200 cfm — yet flow meter readings showed it was running at only half capacity.

Investigation was performed and it was found that these two compressors had variable displacement controls (called turn valves). These controls were designed to cut back the capacity of the compressors — if they were needed to run in part load. However, this type of control was not needed for this particular installation. The controls had been incorrectly adjusted to cut back the compressor capacity, but nobody noticed, due to the lack of flow measurement. The installed central compressor controller incorrectly assumed that when each of the compressors was loaded, it was producing full flow — causing operators to believe that all was well.

After a few quick adjustments by their service provider, the compressors were set back to full load output. The new flow measurement and resulting adjustments had uncovered about 1,000 cfm of extra system capacity and increased the system efficiency.

You may also like:


  • Compressed air fail: Outlet pipe size

  • Compressed air fail: Obsolete compressor controls

  • Compressed air fail: Service factor

  • Compressed air fail: Corrupted VSD settings

Filed Under: Air Compressors, Air Preparation

Primary Sidebar

Fluid Power World Digital Edition

Fluid Power World Digital EditionBrowse the most current issue of Fluid Power World and back issues in an easy to use high quality format. Bookmark, share and interact with the leading design engineering magazine today.

RSS Featured White Papers

  • eBook: Practical Guide to Pneumatics
  • Saving energy and service cost with electric linear systems
  • White Paper-How to Design Efficient Pneumatic Systems!

Fluid Power Design Guides

fluid
“pt
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for Fluid Power Professionals.
Hose Assembly Tips

Footer

Pneumatic Tips

Fluid Power World Network

  • Fluid Power World
  • Hose Assembly Tips
  • Mobile Hydraulic Tips
  • Sealing and Contamination Tips
  • Fluid Power Distributor Lookup

PNEUMATIC TIPS

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2026 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy